Switched Unit Level Monitored Rack PDU VP8959NA3 is a 20A, 208V 0U with input power monitoring and outlet level switching. It has 21 locking IEC C13 and 3 locking IEC C19 receptacles and a NEMA L6-20P providing 3.3kW of power capacity. A Switched rPDU allows you to turn off outlets to avoid accidental overloads and remotely power cycle equipment to reboot unresponsive equipment. The unit comes equipped with an environmental sensor port and dual ethernet ports.
Outlet level control to turn on, off, or reboot individual outlets.
Simple and quick installation in all standard racks or cabinets with included mounting brackets.
Upgradeable and Hot-Swappable monitoring device.
Higher Availability
High Temperature Grade 60°C for high temperature environments.
Bi-stable latching relays significantly reduce idle power draw.
Avoid potential circuit overloads with remote current metering and monitoring of connected loads.
Power sequencing time delays allow users to define the order in which to power up or down connected equipment to avoid circuit overload.
Environmental monitoring capabilities ensure users have critical infrastructure data at their fingertips.
Monitor power consumption at the outlet-level for a detailed view of power distributed to specific equipment with the outlet level option.
Streamlined Power Distribution
Reliable power distribution with local and remote power monitoring options offer quick access to critical power usage information to evaluate energy usage trends and maximize uptime.
Simplify circuit and phase balancing with color-coded receptacles.
Remotely reboot outlets to power cycle unresponsive IT equipment or increase runtime of critical equipment upon power failure with outlet-level control.
Vertiv Geist VP8959NA3 Specifications:
Mechanical
Height
66.25 in. (1683 mm.)
Width
2 in. (51 mm.)
Depth
2.6 in. (66 mm.)
Environmental
Operating Temperature
50°F ─ 140°F (10°C ─ 60°C) for altitudes 10,000 ft (3000 meters) above sea level.
Storage Temperature
-40°F ─ 158°F (-40°C ─ 70°C)
Relative Humidity
0 ─ 95% non-condensing
Input
Voltage
200-240V
Rated Amps
20
kW*
3.3
Phase
A monitoring (kWH, W, VA, PF, V, A)
Input Power Cord Length
10 ft.
Plug
NEMA L6-30P Twistlock
Output
Receptacle/Socket Configuration
(21) U-Lock C13 / (3) U-Lock C19
Form Factor
Vertical
Standards
FCC Part 15 Class A Conformance RoHS Compliant UL & c-UL Listed 60950
Warranty
5-year limited warranty if registered within 120 days ofpurchase, otherwise warranty defaults to 3 years
* Formulas used to calculate the kW: For three-phase: input voltage x max continuous amps x 1.73 = watts