STI Server Technology Switched PDU 0U Vertical (STV-4501D)
Server Technology STV-4501D: Switched PIPS PRO2, Per Input Power Sensing, 0U, (24) IEC C13 and (6) C19, (1) LED Amp Meter in the Middle, 230V, 16A with C20, Pivot Entry, (2) Temp/Humidity Sensor Capable, Circuit Breakers** Input PTCORD-Lx power cord ordered separately **
Standard Stocked: Stocked model, typically ships 7-10 business days from receipt of order.
NOTE: For the greatest compatibility, this PDU does not ship with a power cord. Please choose an appropriate cord from the accessories below.
Price $1,886.00
Discount Pricing Available Call 1.866.722.5776
Rack Units
0U Vertical
The Server Technology PRO2 Switched Rack PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS technology provides billing-grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The PRO2 Switched "Master" PDU can be connected to as many as three PRO2 Switched "Link" PDUs to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking configuration.
STV-4501D Key Features
Network Monitoring
The PRO2 hot-swappable network card provides for HTTP(S), SSH, Telnet,SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
Hot-Swap Network Card
Network access is ensured when power is lost to the Master unit with backup power provided by the primary link unit.
Star Multi-Linking
PRO2 provides the ability to link up to four power circuits using one IP address. Primary link provides backup power to network card.
Temperature/Humidity Monitoring
Master and Link (select products) units each support two external 10ft (3m) T/H probes. Receive SNMP-based alerts and email notifications.
Auto-Flip Current Display
Easy-to-read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in high-density cabinets.
Per-Inlet Power Sensing
Meets ANSI C12.1 for billing-grade accuracy of Current per phase. PIPS includes voltage, active power, apparent power, power factor, and energy.
Branch Current Monitoring
PRO2 monitors current at each breaker branch and provides SNMP-based alerts and emails on high usage that risks a tripped circuit.
Branch Circuit Protection
This rack PDU meets the UL and IEC 60950-1 requirement for branch circuit protection through use of UL489 rated magnetic-hydraulic circuit breakers or UL248 fuses.
Outlet Control
On Switched PDUs, cycle power to individual outlets or groups of outlets to reboot servers. Or, power off unused receptacles.
High Retention Locking Outlets
PRO2 receptacles have high retention and are compatible with P-Lock type power cords.
High Temperature Rating
This product has been tested and approved for safe and reliable operation in 60°C (140°F) data center environments.
Power Pivot
The 90 degree rotatable power cord allows for standardized deployment at any facility no matter where power must be routed.
Flexible Mounting
This rack PDU includes standard button mounts along with provisions for custom mounting brackets (contact us for details).
Color Identification
Choose from six colors to designate circuits for rack PDUs in the data center. Color options include Blue, Red, Green, White, Yellow, and Black.
Cisco EnergyWise1 Compliant
PRO2 meets the requirements set forth by Cisco Systems, Inc. for its EnergyWise program for monitoring of device energy. EnergyWise is a registered trademark of Cisco Systems, Inc.
zLock Dual-side Locking Power Cables Eliminate accidental and vibration power cable disconnects - zLock is the only universal locking power cord that locks both ends.