Accessories for Rittal TopTherm Rack Top Mount AC Units

Interface Board for e-Comfort Controller Equipment - (RS 232, RS 485, RS 422 and PLC interface)
$405.77
Interface Board for e-Comfort Controller Equipment - (RS 232, RS 485, RS 422 and PLC interface)
Interface Board for e-Comfort Controller Equipment - (RS 232, RS 485, RS 422 and PLC interface)

2x Polyurethane Stoppers - Cover unused air outlets - for 3359.xxx, and 3382.xxx
$40.63
2x Polyurethane Stoppers - Cover unused air outlets - for 3359.xxx, and 3382.xxx
2x polyurethane foam stoppers to cover any cold air outlets that are not required. Stoppers are used with roof-mounted cooling units (3359.xxx, and 3382.xxx) and air/water heat exchangers.

2x Polyurethane Stoppers - Cover unused air outlets - for 3209.xxx, 3210.xxx, 3273.xxx, 3383.xxx, 3384.xxx, and 3385.xxx
$50.43
2x Polyurethane Stoppers - Cover unused air outlets - for 3209.xxx, 3210.xxx, 3273.xxx, 3383.xxx, 3384.xxx, and 3385.xxx
2x polyurethane foam stoppers to cover any cold air outlets that are not required. Stoppers are used with roof-mounted cooling units (3209.xxx, 3210.xxx, 3273.xxx, 3383.xxx, 3384.xxx, and 3385.xxx) and air/water heat exchangers.

2x Polyurethane Stoppers - Cover unused air outlets - for 3386.xxx, and 3387.xxx
$57.81
2x Polyurethane Stoppers - Cover unused air outlets - for 3386.xxx, and 3387.xxx
2x polyurethane foam stoppers to cover any cold air outlets that are not required. Stoppers are used with roof-mounted cooling units (3386.xxx, and 3387.xxx) and air/water heat exchangers.

Air duct adaptor for air duct system and shallow air duct system
$121.59
Air duct adaptor for air duct system and shallow air duct system
Air duct adaptor that allows the connection of the spigot from which air is supplied by the cooling unit to the air duct system.

Air duct system For roof-mounted cooling units and roof-mounted air/water heat exchangers
$392.62
Air duct system For roof-mounted cooling units and roof-mounted air/water heat exchangers
Cold air can be routed directly to specific areas of the enclosure using the air duct system.

Air duct system For roof-mounted cooling units and roof-mounted air/water heat exchangers -3386 & 3387
$392.62
Air duct system For roof-mounted cooling units and roof-mounted air/water heat exchangers -3386 & 3387
Cold air can be routed directly to specific areas of the enclosure using the air duct system.

Shallow air duct system For roof-mounted cooling units and roof-mounted air/water heat exchangers
$410.79
Shallow air duct system For roof-mounted cooling units and roof-mounted air/water heat exchangers
Cold air can be routed directly to specific areas of the enclosure using the air duct system.

90° Air Duct Deflector
$120.01
90° Air Duct Deflector
Air Duct Deflector (RAL 7035) for targeted air deflection at the end of the flat duct.

Flat Duct Extension Kit - 59"L
$262.76
Flat Duct Extension Kit - 59"L
Extension kit for air duct system and flat air duct system for width, depth or height length extensions in TS enclosures.

32ft (10m) Condensate hose  - 12 x 2mm thick
$121.16
32ft (10m) Condensate hose - 12 x 2mm thick
32ft (10m) Condensate hose - 12 x 2mm thick

Primary/secondary cable For SK BUS system
$415.22
Primary/secondary cable For SK BUS system
Primary-secondary cable For SK BUS system

RiDiag II - Cooling Unit Monitoring Software
$467.83
RiDiag II - Cooling Unit Monitoring Software
For the diagnosis, maintenance and long-term data capture of TopTherm units with e-Comfort controller. RiDiag logs equipment data and prepares an error list.

Door-operated switch
$92.66
Door-operated switch
Door-operated switch

Filter Mats for Cooling Units - 3273.xxx, 3382.xxx, 3383.xxx, 3384.xxx, 3385.xxx, and 3359.xxx
$72.93
Filter Mats for Cooling Units - 3273.xxx, 3382.xxx, 3383.xxx, 3384.xxx, 3385.xxx, and 3359.xxx
Filter mats may be used for extreme conditions, particularly when cooling units are used in a dusty environments.

Metal Filters for Cooling Units - 3273.xxx, 3382.xxx, 3383.xxx, 3384.xxx, 3385.xxx, and 3359.xxx
$316.22
Metal Filters for Cooling Units - 3273.xxx, 3382.xxx, 3383.xxx, 3384.xxx, 3385.xxx, and 3359.xxx
Particularly when cooling units are used in a dusty and oily environments, it is advisable to use washable metal filters.

Filter Mats For Cooling Units - 3386.xxx & 3387.xxx
$84.13
Filter Mats For Cooling Units - 3386.xxx & 3387.xxx
Filter mats may be used for extreme conditions, particularly when cooling units are used in a dusty environments.

Metal Filters for Cooling Units - 3386.xxx & 3387.xxx
$346.03
Metal Filters for Cooling Units - 3386.xxx & 3387.xxx
Particularly when cooling units are used in a dusty and oily environments, it is advisable to use washable metal filters.

Quick-change frame for roof-mounted cooling units - 3383.xxx, 3384.xxx, 3385.xxx, 3209.xxx, and 3210.xxx
$597.91
Quick-change frame for roof-mounted cooling units - 3383.xxx, 3384.xxx, 3385.xxx, 3209.xxx, and 3210.xxx
Use the quick-change roof-mount frame for easily removing a cooling unit during servicing work - shorted assembly times and hence minimized downtime. Includes Integral drainage through eliminiating ingress of oil.

Quick-change frame for roof-mounted cooling units - 3386.xxx & 3387.xxx
$711.64
Quick-change frame for roof-mounted cooling units - 3386.xxx & 3387.xxx
Use the quick-change roof-mount frame for easily removing a cooling unit during servicing work - shorted assembly times and hence minimized downtime. Includes Integral drainage through eliminiating ingress of oil.

Quick-change frame for roof-mount cooling units - 3359.xxx and 3382.xxx
$573.27
Quick-change frame for roof-mount cooling units - 3359.xxx and 3382.xxx
Use the quick-change roof-mount frame for easily removing a cooling unit during servicing work - shorted assembly times and hence minimized downtime. Includes Integral drainage through eliminiating ingress of oil.

Rack Roof Plate with cutouts for AC  - 23.6"W x 23.6"D Enclosures
$329.33
Rack Roof Plate with cutouts for AC - 23.6"W x 23.6"D Enclosures
The cut-out in the roof plate is such that the roof-mounted cooling units are positioned centrally on the enclosure. 3383.xxx, 3384.xxx, 3385.xxx, 3209.xxx, 3210.xxx, 3273.xxx, and 8801.380 Rittal cooling units.

Rack Roof Plate with cutouts for AC  - 31.5"W x 23.6"D Enclosures
$369.23
Rack Roof Plate with cutouts for AC - 31.5"W x 23.6"D Enclosures
The cut-out in the roof plate is such that the roof-mounted cooling units are positioned centrally on the enclosure. 3383.xxx, 3384.xxx, 3385.xxx, 3209.xxx, 3210.xxx, 3273.xxx, and 8801.380 Rittal cooling units.

Rack Roof Plate with cutouts for AC  - 47.24"W x 23.6"D Enclosures
$389.33
Rack Roof Plate with cutouts for AC - 47.24"W x 23.6"D Enclosures
The cut-out in the roof plate is such that the roof-mounted cooling units are positioned centrally on the enclosure. 3383.xxx, 3384.xxx, 3385.xxx, 3209.xxx, 3210.xxx, 3273.xxx, and 8801.380 Rittal cooling units.

Rack Roof Plate with cutouts for AC  - 31.5"W x 23.6"D Enclosures
$380.68
Rack Roof Plate with cutouts for AC - 31.5"W x 23.6"D Enclosures
The cut-out in the roof plate is such that the roof-mounted cooling units are positioned centrally on the enclosure. 3386.xxx, 3387.xxx Rittal cooling units.

Support Rails - Outer Mounting Level - 15.47"W x D Enclosures
$274.49
Support Rails - Outer Mounting Level - 15.47"W x D Enclosures
Support strips are cross-rail pieces for mounting specialized equipment such as air duct kits into a TS, SE, CM or TP server rack.

Support Rails - Outer Mounting Level - 19.69"W x D Enclosures
$387.78
Support Rails - Outer Mounting Level - 19.69"W x D Enclosures
Support strips are cross-rail pieces for mounting specialized equipment such as air duct kits into a TS, SE, CM or TP server rack.

Support Rails - Outer Mounting Level - 23.62"W x D Enclosures
$445.13
Support Rails - Outer Mounting Level - 23.62"W x D Enclosures
Support strips are cross-rail pieces for mounting specialized equipment such as air duct kits into a TS, SE, CM or TP server rack.

Support Rails - Outer Mounting Level - 31.5"W x D Enclosures
$518.51
Support Rails - Outer Mounting Level - 31.5"W x D Enclosures
Support strips are cross-rail pieces for mounting specialized equipment such as air duct kits into a TS, SE, CM or TP server rack.

Support Rails - Inner Level or Door Mounting - for 15.75"W Encl. or 19.69"W Door
$298.37
Support Rails - Inner Level or Door Mounting - for 15.75"W Encl. or 19.69"W Door
Support strips are cross-rail pieces for mounting specialized equipment such as air duct kits into a TS, SE, CM or TP server rack.

Support Rails - Inner Level or Door Mounting - for 19.69"W Encl. or 23.62"W Door
$325.49
Support Rails - Inner Level or Door Mounting - for 19.69"W Encl. or 23.62"W Door
Support strips are cross-rail pieces for mounting specialized equipment such as air duct kits into a TS, SE, CM or TP server rack.

Support Rails - Inner Level or Door Mounting  - for 31.5"W Encl. or 35.43"W Door
$416.40
Support Rails - Inner Level or Door Mounting - for 31.5"W Encl. or 35.43"W Door
Support strips are cross-rail pieces for mounting specialized equipment such as air duct kits into a TS, SE, CM or TP server rack.

Support Rails - Inner Mounting Level - for 23.62"W Door
$349.37
Support Rails - Inner Mounting Level - for 23.62"W Door
Support strips are cross-rail pieces for mounting specialized equipment such as air duct kits into a TS, SE, CM or TP server rack.

Support Rails - Door Mounting - for 15.75"W Door
$201.21
Support Rails - Door Mounting - for 15.75"W Door
Support strips are cross-rail pieces for mounting specialized equipment such as air duct kits into a TS, SE, CM or TP server rack.

Support Rails - Door Mounting - for 31.5"W Door
$368.53
Support Rails - Door Mounting - for 31.5"W Door
Support strips are cross-rail pieces for mounting specialized equipment such as air duct kits into a TS, SE, CM or TP server rack.

Support Rails - Door Mounting - for 39.37"W Door
$448.26
Support Rails - Door Mounting - for 39.37"W Door
Support strips are cross-rail pieces for mounting specialized equipment such as air duct kits into a TS, SE, CM or TP server rack.