Mechanical | |
Height | 3.4 in. (8.6 cm.) |
Width | 17.2 in. (43.7 cm.) |
Depth | 23.6 in. (59.9 cm.) |
Weight | 63.9 lbs. (29.0 kg.) |
Environmental | |
Heat Dissipation (BTU) | Line: 838, Bat: 1348 |
Audible Noise | <50 dB |
Operating Temperature | -20˚C (-4˚F) to +40˚C (104˚F) with batteries and -25˚C (-13˚F) to +55˚C (131 ˚F) without batteries |
Storage Temperature | -20°C (-4°F) to +40°C (104°F) with batteries and -25°C (-13°F) to +55°C (131 °F) without batteries |
Relative Humidity | 5–90% non-condensing |
Electrical Input | |
Connection | 5-20P |
Input Cord | 6 ft. (1.8 m) |
Input Voltage Range | 90-138 Vac |
Nominal Voltage | 120V |
Frequency | 50/60 Hz |
Frequency Range | 45–65 Hz |
Nominal Current | 16.7 A |
Breaker Ratings | 20A |
Generator Compatability | Yes |
Electrical Output | |
Output Receptacles | (6) 5-20R, (1) L5-20R |
On Utility Voltage Regulation | ±3% of nominal |
On Battery Voltage Regulation | ±3% of nominal |
Voltage Wave Shape (On Battery) | Sine wave |
Power Factor | 0.9 |
Frequency Regulation | ±3% Hz online |
Load Crest Factor | 3 to 1 |
Battery | |
Maximum Number of Battery Packs | 4 |
Battery Type | 72 Vdc; (6) 12V, 9 Ah |
Half Load Runtime (in mins) | 26 |
Full Load Runtime (in mins) | 9 |
Battery Replacement | Hot-swappable internal and external batteries |
Start On Battery | Allows start of UPS without utility input |
Recharge Time | Internal batteries: 3 hours. 1 EBM: 9 hours; 2 EBM: 15 hours; 3 EBM: 21 hours; 4 EBM: 27 hours |
Communications | |
User Interface | Graphical LCD with blue backlight and text in English, French, German, Russian and Spanish |
LEDs | Four status-indicating LEDs |
Communication Ports | (1) USB, (1) RS-232 serial, Relay output (common alarm standard) |
Communications Slot | Optional communication slots (BD Slot) |
Optional Communication Cards | SNMP/Web card for direct control and monitoring in SNMP-based networks, monitoring of UPS status and meters through Web browser interface Relay card for integration to industrial environment and building management systems, remote shutdown for IBM AS/400 systems |
Power Management Software | Bundled software suite CD |
General | |
Topology | Online, double-conversion |
Configuration | Rackmount |
Color | Black |
Rating (VA/Watts) | 2000/1800 |
Diagnostics | Full system self-test |
Efficiency | >95% in high-efficiency mode; >86% in online mode |
UPS Bypass | Automatic bypass |
Rail Kit Included | Included with all rackmount units |
Warranty | Two-year factory warranty |
Remote Emergency Power off (REPO) | Emergency shutdown control through the REPO port |
Standards | |
Safety markings | UL, cUL, VCCI |
EMC Markings | FCC Class A, EN55022 Class A |
RoHS Compliance | Yes |