Powerware PW5125-2200b Tower UPS Power

Eaton 5PX 2200 VA Line-Interactive Rack / Tower UPS
$2,123.46
Eaton 5PX 2200 VA Line-Interactive Rack / Tower UPS
  • Voltage: 208V
  • Power Rating: 2200VA/1980W
  • Input: IEC C20
  • Output: (8) C13 + (1) C19
  • Form Factor: 2U Rackmount or Tower
 

Please note, the Eaton Powerware PW5125-2200b (5125 UPS family) UPS has been discontinued and replaced by the Eaton 5P and 5PX series. The recommended replacement is the Eaton 5P 2200iRT. For other upgrade options please contact us.

The Powerware PW5125-2200b Line-interactive Tower UPS delivers cost-effective power protection for PCs, workstations, and servers.

  • ABM technology significantly increases battery service life
  • Buck and Double Boost voltage regulation corrects voltage fluctuations and delivers pure sine wave output
  • Extended runtime capability with Extended Battery Modules (EBMs)
  • Load segments maximize runtime for critical devices
  • Hot-swappable batteries simplify service
Eaton Powerware PW5125-2200b Tower UPS Power

Eaton Powerware

PW 5125 2200b Specifications:

Mechanical  
Dimensions (HxWxD) 9.84 x 8.07 x 19.41 in. (250 x 205 x 493 mm.)
Weight 68.3 lbs. (31.0 kg.)
Electrical Input  
Power Rating 2080VA / 1600W
Nominal Voltage 208 Vac
Input Voltage Ranges (for user-selectable voltages) Low voltage: 77-152 V; High voltage: 154-288 V
Operating Frequency 50/60 Hz, Auto-sensing
Frequency Range 46-65 Hz
Connections  
Input Connections IEC-320-15A, inlet (Includes (2) each IEC interconnect cables.)
Output Receptacles (9) IEC-320-10A (C13)
Battery  
Battery Type Sealed, lead-acid; maintenance free
Battery Replacement Hot-swappable internal batteries and external batteries modules
Recharge Time <3 hours to 90% usable capacity
Start-On-Battery Allows start of UPS without utility input
Electrical Output  
On Utility Voltage Regulation -10% to +6% of nominal
On Battery Voltage Regulation  ±5% RMS
Voltage Wave Shape (on battery) Sine Wave
Output Protection Short circuit protection
Communications  
User Interface Front Control Panel
Audible Alarms For various UPS alarm conditions, including: On Battery, Low Battery, Overload, UPS fault
Network Transient Protector  UL 497 A, in/out jacks RJ45 (high voltage models network protection) &
RJ11 (low voltage models modem protection)
X-Slot Interface RS-232 Single Serial Card (standard),
other options available: See available Options Chart
Cable 6-foot communications cable included
Power Management Software Powerware Software Suite CD-ROM (bundled with UPS)
General  
Diagnostics Full system self-test on power up
UPS Bypass No Bypass, Internal Bypass
Transfer Time 2-4ms typical
Overload (normal operation) 110% overload, shutdown after 3 minutes.
150% overload, shut down 10 cycles
Environmental  
Operating Temperature 0 to 40º C (32 to 104º F)
Storage Temperature -15 to 50º C (5 to 122º F)
Relative Humidity 0% to 95% non-condensing
Lightning & Surge Protection ANSI/IEEE C62.41 (IEEE 587), IEC61000-4-5
Surge Energy Rating 480 Joules
Audible Noise Less than 40 dBA typical
 Altitude 3000m (10,000 ft) without derating