Please note, the Liebert PS1500RT3-120XR has been discontinued. To discuss alternative options, please contact your Server Racks Online sales representative.
The Liebert PSI-XR PS1500RT3-120XR is a 2U Line-interactive UPS system, 1500VA/1350W/120V. The Liebert PSI-XR are compact, line-interactive UPS systems designed especially for IT applications such as network closets and small data centers. They provide reliable power protection for servers, critical nodes, network workstations, large network peripherals, network routers, bridges, hubs and other electronic equipment. Liebert PSI-XR is compatible with matching battery cabinets to extend the on-battery operating time.
The Liebert PSI-XR standard model may be rackmounted or set up in tower configuration. The UPS includes data line surge protection, transient voltage surge protection, and optional communications for shutdown and reporting. The XR model offers extended battery runtime, with the addition of external battery cabinets. A rack mounting rail kit is included as standard.
Price $928.00
Rack Units
2U
Dimensions
3.5"H x 17.3"W x 19.3"D
Liebert PS1500RT3-120XR Features:
Flexibility:
Provides six battery-backed outlets depending on model and size, allowing additional equipment to be connected to the UPS via the 15 Amp receptacles.
Configurable input voltage window allows the UPS to be properly matched to the incoming utility power.
Automatic Frequency Sensing allows the UPS to automatically adjust to the input frequency, 50Hz or 60Hz.
LED display panel rotates 90° to make the readout of the LED display easy to see in rack or tower position.
Optional External Battery Cabinets for XR models provide extended runtime for applications that require longer backup time (sold separately)
Higher Availability:
Provides network surge protection for equipment connected to the UPS via the RJ-45.
Offers multiple audible and visual alarms to immediately alert you to an input voltage fluctuation (buck/boost), output overload, low battery or replace battery condition.
Greater than five minutes of battery backup time at full load when utility fails.
Comprehensive analysis of the condition of the batteries within the UPS and will notify you when the internal batteries need to be replaced. The battery test feature can also be programmed for automatic operation using Liebert shutdown software.
Allows fast and easy maintenance with user-replaceable hot-swappable batteries.
Provides remote emergency power off for safe emergency shutdown.
Lowest Total Cost Of Ownership:
0.9 Output Power Factor provides more power for your protected load, and more energy efficient operation.
Offers the most competitive price in its class, when ordered as a Network Solutions Package with factory-installed Liebert IntelliSlot Web Card.
Ships with batteries connected and charged, reducing installation time and costs.
Protects your investment with a standard two-year warranty with paid shipping both ways. Also available with optional extensions of one year or three years.
Ideally Suited For:
PCs
Network workstations
Servers
Network closets
Large network peripherals
VoIP
Liebert PS1500RT3-120XR Specifications:
Mechanical
Height
3.5 in. (88 mm.)
Width
17.3 in. (440 mm.)
Depth
19.3 in. (490.5 mm.)
Weight
62 lbs. (28 kg.)
Environmental
Operating Temperature, ˚F (˚C)
32 to 104 (0 to 40)
Storage Temperature, ˚F (˚C)
5 to 104 (-15 to 40)
Relative Humidity
0% to 90%, non-condensing
Operating Altitude
Up to 3000m (10,000 ft) at 35˚C (95˚F) without derating
Audible Noise
<40 dBA, internal fan(s) Off; <45 dBA, internal fan(s) On
Power Rating, VA/W
1500VA/1350W
Input AC Parameters
Surge Protection
570J
Voltage Range Without Battery Operation
83 to 159 VAC (configurable)
Frequency Range
45~65Hz, (0.5Hz)
Input Power Cord, 10ft (3m) attached
NEMA 5-15P plug
Output Receptacles
(6) NEMA 5-15R
Voltage (Normal Mode)
110/120/127 VAC (configurable)
Voltage (Battery Mode)
110/120/127 VAC; 5% before low-battery warning
Transfer Time
4-6 ms typical
Battery Waveform
Sinewave
Battery Parameters
Type
Valve-regulated, non-spillable, lead acid
Recharge Time
5 hours to 90% of rated capacity, after full discharge into resistive load