STI Server Technology Basic PDU 0U Vertical (CB-26V0AE01F6)Server Technology CB-26V0AE01F6: Basic PDU, (24) IEC C13 + (2) IEC C19 Outlets, 120V, 200-240V, 230V, 16A, IEC C20 Inlet, Bottom/Front Cord Entry, Doghouse Circuit Breakers (Input Cord Must Be Ordered Separately) Input Power Capacity (kW): | 3.6 | Input Plug Type: | IEC C20 100-240V Inlet | Input Current (A): | 16 | Input Current Rated (A): | 16 | Input Nominal Voltage (V): | 208 | Input Phase: | 1-Phase (L-N) | Input Cord Location: | Bottom/Front | Outlet Form Factor: | Conventional | Total Outlets: | 26 | IEC C13 Count: | 24 | IEC C19 Count: | 2 |
arrow_drop_downSee More Specifications Standard Stocked: Stocked model, typically ships 7-10 business days from receipt of order. NOTE: For the greatest compatibility, this PDU does not ship with a power cord. Please choose an appropriate cord from the accessories below. |
Price $397.00Discount Pricing Available Call 1.866.722.5776 |
| Rack Units | 0U Vertical | |
| | The Server Technology Basic PDU provides reliable power distribution for installing IT equipment into the rack/cabinet.
CB-26V0AE01F6 Key Features Branch Circuit Protection This rack PDU meets the UL and IEC 60950-1 requirement for branch circuit protection through use of UL489 rated magnetic-hydraulic circuit breakers or UL248 fuses. Flexible Mounting This rack PDU includes standard button mounts along with provisions for custom mounting brackets (contact us for details). High Retention Locking Outlets PRO2 receptacles have high retention and are compatible with P-Lock type power cords. Color Identification Choose from six colors to designate circuits for rack PDUs in the data center. Color options include Blue, Red, Green, White, Yellow, and Black.
CB-26V0AE01F6 SpecificationsInput Power Capacity (kW): | 3.6 | Input Plug Type: | IEC C20 100-240V Inlet | Input Current (A): | 16 | Input Current Rated (A): | 16 | Input Nominal Voltage (V): | 208 | Input Phase: | 1-Phase (L-N) | Input Cord Location: | Bottom/Front | Outlet Form Factor: | Conventional | Total Outlets: | 26 | IEC C13 Count: | 24 | IEC C19 Count: | 2 |
CB81 Family SpecificationsBranch Monitoring: | None | Branch Overcurrent Protection: | 5 kAIC | Branch Overcurrent Protection Type: | Circuit Breaker: 2-pole | Dual Input: | No | High Retention Outlets: | No | Input Current Display: | | Input Monitoring: | None | Locking Outlets: | No | Max Operating Temperature: | 50 °C | Fast Movers: | No | Mounting: | 0U Vertical | Outlet Monitoring: | None | PDU Platform: | None | Power Pivot Input: | No | Product Height (inch): | 35.5 | Product Height (mm): | 902 | Product Max Depth (inch): | 2.5 | Product Max Depth (mm): | 64 | Product Nominal Depth (inch): | 1.75 | Product Nominal Depth (mm): | 45 | Product Width (inch): | 1.75 | Product Width (mm): | 45 |
CB-26V0AE01F6 Additional InformationCB81 Family DrawingsCB81 Family Downloads
For More Options See:
*PDU is also known as CDU (Cabinet Distribution Unit).
| | | | | | |