STI Server Technology Basic CDU Horizontal 1U (CB-12H2-L630)

The Server Technology CB-12H2-L630 CDU is a 200-240V, 30 amp, basic PDU with 12 IEC C13 outlets and a locking NEMA L6-30P in-feed plug. This unit provides robust, dependable power distribution. The Server Technology Sentry basic PDUs branch circuit protection is accomplished via UL-listed Bussman SC fuses for compliance with UL/CSA/EN 60950-1 standards. The Sentry Basic CDU product family provides both an industrial grade device and an economical solution for your power distribution needs.

CB-12H2-L630 Features

  • Horizontal mounting, 1U
  • Steel Case Enclosure
  • Industrial Grade Outlet
  • High Quality Powder Coat
  • UL/CSA/EN 60950-1 standard compliant

Standard Stocked: Stocked model, typically ships 7-10 business days from receipt of order.

**NOTE: A 10 foot power cord is included at no additional cost.

NEMA L6-30 PlugPTCORD: IEC 60320/C19 to L6-30P, Twist-lock

Server Technology CB-12H2-L630 - Click to enlarge

Server Technology

Price
$190.00
Discount Pricing Available
Call 1.866.722.5776

Mounting Bracket Options
Include Mounting Bracket KIT-MBVPT-1B (no charge)
No Mounting Bracket Needed

The Server Technology Basic PDU provides reliable power distribution for installing IT equipment into the rack/cabinet.


CB-12H2-L630 Key Features

  • Pdu colors

    Color Identification

    Choose from six colors to designate circuits for rack PDUs in the data center. Color options include Blue, Red, Green, White, Yellow, and Black.

  • Branch Circuit Protection - Rack PDU Feature

    Branch Circuit Protection

    This rack PDU meets the UL and IEC 60950-1 requirement for branch circuit protection through use of UL489 rated magnetic-hydraulic circuit breakers or UL248 fuses.



CB-12H2-L630 Specifications

Input Power Capacity (kW): 5.0
Input Plug Type: NEMA L6-30P
Input Current (A): 30
Input Current Rated (A): 24
Input Nominal Voltage (V): 208
Input Phase: 1-Phase (L-L)
Input Cord Location: Horizontal
Total Outlets: 12
IEC C13 Count: 12

CB05 Family Specifications

Branch Monitoring: None
Branch Overcurrent Protection: 100 kA
Branch Overcurrent Protection Type: Fuse Holder
Dual Input: No
High Retention Outlets: Yes
Input Current Display: None
Input Monitoring: None
Locking Outlets: Yes
Max Operating Temperature: 40 °C
Fast Movers: No
Mounting: 1U Horizontal
Outlet Monitoring: None
PDU Platform:
Power Pivot Input: No
Product Height (inch): 1.75
Product Height (mm): 45
Product Max Depth (inch): 2.25
Product Max Depth (mm): 58
Product Nominal Depth (inch): 2.25
Product Nominal Depth (mm): 58
Product Width (inch): 17.0
Product Width (mm): 432


CB-12H2-L630 Summary

Mechanical
Lenght 17"
Width 1.75"
Depth 2.25"
Input Voltages200-240V
Rated Amperage30 amp
Outlets12 IEC C13
Standards 
Agency ApprovalsUS & Canada (cTUVs mark) to UL 60950-1:2003 and CAN/CSA 22.2 No. 60950-1-03 FCC Class A, Part 15 CISPR 22


CB-12H2-L630 Additional Information

CB05 Family Drawings

CB05 Family Downloads


For More Options See:

Server Tech PDUs

Sentry Basic CDU Series

*PDU is also known as CDU (Cabinet Distribution Unit).



Server Rack Cable Management
Server Rack Cable Management
Cable Management Rings, Rackmount Cable Organizers, Cable Ties, Patch Panels, Cat5 Patch Cables, Fiber Optic Cables, Power Cords
 
zLock Dual-side Locking Power Cables
zLock Dual-side Locking Power Cables
Eliminate accidental and vibration power cable disconnects - zLock is the only universal locking power cord that locks both ends.
Power Cords & Extension Power Cords
Power Cords & Extension Power Cords
Power Cords & Extension Cords available in a huge variety of connectors and cord lengths!
 
UPS Backup Power - Rack Mount & Tower UPS
UPS Backup Power - Rack Mount & Tower UPS
Off Line (Basic), Line Interactive (Intermediate), and On Line Double Conversion (Advanced) Uninterruptable Power Systems
 
Automatic Transfer Switches (ATS) - Fail-Safe Power Redundancy
Automatic Transfer Switches (ATS) - Fail-Safe Power Redundancy
Automatically switch power inputs if either in-feed goes down - Fail-Safe N+1 Power Redundancy.
Question: input is 200-240V, what is OUTPUT voltage?
Answer: Thank you for your inquiry. The output voltage is 208V.