STI Server Technology Switched PDU 0U Vertical (C1W24VS-YCFA11C9)

Server Technology C1W24VS-YCFA11C9: Switched PRO1, 0U, 18 x IEC C13 and 6 x IEC C19 Outlets, 1 x NEMA 5-20R Utility Outlet, 3 x LED Amp Meters, 3-phase Wye 30A Input w/ NEMA L21-30P Connector, 10ft (3m) Cord Set, (2) Temperature/Humidity Sensor Capable, with Retractable Fuses

Input Power Capacity (kW): 8.6
Input Plug Type: NEMA L21-30P
Input Current (A): 30
Input Current Rated (A): 24
Input Nominal Voltage (V): 208
Input Phase: 3-Phase Wye (L-L)
Input Cord Location: Bottom/Front
Total Outlets: 24
IEC C13 Count: 18
IEC C19 Count: 6
Utility Outlet: 1

arrow_drop_downSee More Specifications

Standard Stocked: Stocked model, typically ships 7-10 business days from receipt of order.

Server Tech C1W24VS-YCFA11C9 - Click to enlarge

Server Technology

Price
$1,796.00
Discount Pricing Available
Call 1.866.722.5776
Rack Units0U Vertical

Mounting Bracket Options
Include Mounting Bracket KIT-MBVPT-1B (no charge)
No Separate Mounting Bracket Needed

The Server Technology PRO1 Switched Rack PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS technology provides billing-grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The PRO1 Switched "Master" PDU can be connected to as many as three PRO1 Switched "Link" PDUs to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking configuration.



C1W24VS-YCFA11C9 Specifications

Input Power Capacity (kW): 8.6
Input Plug Type: NEMA L21-30P
Input Current (A): 30
Input Current Rated (A): 24
Input Nominal Voltage (V): 208
Input Phase: 3-Phase Wye (L-L)
Input Cord Location: Bottom/Front
Total Outlets: 24
IEC C13 Count: 18
IEC C19 Count: 6
Utility Outlet: 1

1F23 Family Specifications

Branch Monitoring: Sense
Branch Overcurrent Protection: 100 kA
Branch Overcurrent Protection Type: Fuse Retractor
Dual Input: No
High Retention Outlets: Yes
Input Current Display: Auto-Orient
Input Monitoring: Current (A)
Locking Outlets: Yes
Max Operating Temperature: 50 °C
Fast Movers: No
Mounting: 0U Vertical
Outlet Monitoring: None
PDU Platform:
Power Pivot Input: No
Product Height (inch): 69.0
Product Height (mm): 1753
Product Max Depth (inch): 3.0
Product Max Depth (mm): 77
Product Nominal Depth (inch): 2.25
Product Nominal Depth (mm): 58
Product Width (inch): 1.75
Product Width (mm): 45



C1W24VS-YCFA11C9 Additional Information

1F23 Family Drawings

1F23 Family Downloads


For More Options See:

Server Tech PDUs


*PDU is also known as CDU (Cabinet Distribution Unit).




Server Rack Cable Management
Server Rack Cable Management
Cable Management Rings, Rackmount Cable Organizers, Cable Ties, Patch Panels, Cat5 Patch Cables, Fiber Optic Cables, Power Cords
 
zLock Dual-side Locking Power Cables
zLock Dual-side Locking Power Cables
Eliminate accidental and vibration power cable disconnects - zLock is the only universal locking power cord that locks both ends.
Power Cords & Extension Power Cords
Power Cords & Extension Power Cords
Power Cords & Extension Cords available in a huge variety of connectors and cord lengths!
 
UPS Backup Power - Rack Mount & Tower UPS
UPS Backup Power - Rack Mount & Tower UPS
Off Line (Basic), Line Interactive (Intermediate), and On Line Double Conversion (Advanced) Uninterruptable Power Systems
 
Automatic Transfer Switches (ATS) - Fail-Safe Power Redundancy
Automatic Transfer Switches (ATS) - Fail-Safe Power Redundancy
Automatically switch power inputs if either in-feed goes down - Fail-Safe N+1 Power Redundancy.