STI Server Technology Smart PDU 0U Vertical (C1S24VS-DBFA11AC)

Server Technology C1S24VS-DBFA11AC: Smart PRO1, 0U, 24 x IEC C13 Outlets, 3 x LED Amp Meters, 3 Phase Delta 20A Input w/ NEMA L15-20P Connector, 10ft (3m) Bottom/Front Cord Set, (2) Temperature/Humidity Sensor Capable, with Retractable Fuses

Input Power Capacity (kW): 5.7
Input Plug Type: NEMA L15-20P
Input Current (A): 20
Input Current Rated (A): 16
Input Nominal Voltage (V): 208
Input Phase: 3-Phase Delta (L-L)
Input Cord Location: Bottom/Front
Total Outlets: 24
IEC C13 Count: 24
Utility Outlet: 0

arrow_drop_downSee More Specifications

Please Note: This PDU is built-to-order. Some models require a minimum order quantity of 50 pcs.

Server Tech C1S24VS-DBFA11AC - Click to enlarge

Server Technology

Price
$1,031.00
Discount Pricing Available
Call 1.866.722.5776
Rack Units0U Vertical

Mounting Bracket Options
Include Mounting Bracket KIT-MBVPT-1B (no charge)
No Separate Mounting Bracket Needed

The Server Technology PRO1 Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS technology provides billing-grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The PRO1 Smart "Master" PDU can be connected to as many as three (with optional module) PRO1 Smart "Link" PDUs to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking configuration.


C1S24VS-DBFA11AC Key Features

  • Network monitoring test

    Network Monitoring

    The PRO2 hot-swappable network card provides for HTTP(S), SSH, Telnet,SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.

  • Hot-Swap Network Card - Rack PDU Feature

    Hot-Swap Network Card

    Network access is ensured when power is lost to the Master unit with backup power provided by the primary link unit.

  • Star Multi-Linking - Rack PDU Feature

    Star Multi-Linking

    PRO2 provides the ability to link up to four power circuits using one IP address. Primary link provides backup power to network card.

  • Environmental Monitoring - Rack PDU Feature

    Temperature/Humidity Monitoring

    Master and Link (select products) units each support two external 10ft (3m) T/H probes. Receive SNMP-based alerts and email notifications.

  • Input current monitor

    Auto-Flip Current Display

    Easy-to-read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in high-density cabinets.

  • PIPS - Per Inlet Power Sensing - Rack PDU Feature

    Per-Inlet Power Sensing

    Meets ANSI C12.1 for billing-grade accuracy of Current per phase. PIPS includes voltage, active power, apparent power, power factor, and energy.

  • Branch Circuit Protection - Rack PDU Feature

    Branch Circuit Protection

    This rack PDU meets the UL and IEC 60950-1 requirement for branch circuit protection through use of UL489 rated magnetic-hydraulic circuit breakers or UL248 fuses.

  • High retention outlets

    High Retention Locking Outlets

    PRO2 receptacles have high retention and are compatible with P-Lock type power cords.

  • Flexible Mounting - Rack PDU Feature

    Flexible Mounting

    This rack PDU includes standard button mounts along with provisions for custom mounting brackets (contact us for details).

  • Pdu colors

    Color Identification

    Choose from six colors to designate circuits for rack PDUs in the data center. Color options include Blue, Red, Green, White, Yellow, and Black.

  • Cisco dev

    Cisco EnergyWise1 Compliant

    PRO2 meets the requirements set forth by Cisco Systems, Inc. for its EnergyWise program for monitoring of device energy. EnergyWise is a registered trademark of Cisco Systems, Inc.



C1S24VS-DBFA11AC Specifications

Input Power Capacity (kW): 5.7
Input Plug Type: NEMA L15-20P
Input Current (A): 20
Input Current Rated (A): 16
Input Nominal Voltage (V): 208
Input Phase: 3-Phase Delta (L-L)
Input Cord Location: Bottom/Front
Total Outlets: 24
IEC C13 Count: 24
Utility Outlet: 0

1C23 Family Specifications

Branch Monitoring: None
Branch Overcurrent Protection: 100 kA
Branch Overcurrent Protection Type: Fuse Retractor
Dual Input: No
High Retention Outlets: Yes
Input Current Display: Auto-Orient
Input Monitoring: Current (A)
Locking Outlets: Yes
Max Operating Temperature: 50 °C
Fast Movers: No
Mounting: 0U Vertical
Outlet Monitoring: None
PDU Platform:
Power Pivot Input: No
Product Height (inch): 69.0
Product Height (mm): 1753
Product Max Depth (inch): 3.0
Product Max Depth (mm): 77
Product Nominal Depth (inch): 2.25
Product Nominal Depth (mm): 58
Product Width (inch): 1.75
Product Width (mm): 45



C1S24VS-DBFA11AC Additional Information

1C23 Family Drawings

1C23 Family Downloads


For More Options See:

Server Tech PDUs


*PDU is also known as CDU (Cabinet Distribution Unit).




Server Rack Cable Management
Server Rack Cable Management
Cable Management Rings, Rackmount Cable Organizers, Cable Ties, Patch Panels, Cat5 Patch Cables, Fiber Optic Cables, Power Cords
 
zLock Dual-side Locking Power Cables
zLock Dual-side Locking Power Cables
Eliminate accidental and vibration power cable disconnects - zLock is the only universal locking power cord that locks both ends.
Power Cords & Extension Power Cords
Power Cords & Extension Power Cords
Power Cords & Extension Cords available in a huge variety of connectors and cord lengths!
 
UPS Backup Power - Rack Mount & Tower UPS
UPS Backup Power - Rack Mount & Tower UPS
Off Line (Basic), Line Interactive (Intermediate), and On Line Double Conversion (Advanced) Uninterruptable Power Systems
 
Automatic Transfer Switches (ATS) - Fail-Safe Power Redundancy
Automatic Transfer Switches (ATS) - Fail-Safe Power Redundancy
Automatically switch power inputs if either in-feed goes down - Fail-Safe N+1 Power Redundancy.