ATS-H24US-30A_L530 2U Dual Circuit Metered ATS

InfraPower ATS-H24US-30A_L530

  • Voltage: 110V, 50/60Hz
  • Max. Amperage: 30A
  • Power Input: (2) NEMA L5-30P
  • Outlets: (24) NEMA 5-20R
  • Form Factor: 2U
  • Dual Circuit

InfraPower Metered Automatic Transfer Switch with dual power input provides reliable and redundant power for single-corded equipment. By the input preference switch, users can define the preferred power source. If the primary source is unavailable, the ATS will seamlessly source power from the secondary source without power interruption and downtime. The entire ATS series are designed with a local current meter to easily observe power status and device load.

ATS-H24US-30A_L530 2U Dual Circuit Metered ATS - Click to enlarge


Price: $1,274.00
NOW: $1,092.00
Save: $182.00
Rack Units2U
Dimensions17.2 in W x 24.8 in D x 3.5 in H

InfraPower Metered ATS Features

  • Input Switching Locally and Over IP - Local power input switching is essential, especially for conducting maintenance in the data center. Alternatively, InfraPower intelligent ATS enables users to switch power input over IP, saving manpower and providing a prompt way to switch power input.
  • Auto Switching Relay for Seamless Power Transfer - InfraPower ATS offers a simple but reliable solution for automatically sensing power loss and seamlessly switching to a secondary power source. The power source transfer time is seamless to the connected equipment, making sure that the switching occurs safely between the two input power sources. After switching to a backup power source, it can also switch power back to the primary input after power has been restored.
  • Power Redundancy for Single Corded Devices - Most data centers provide power source redundancy in order to ensure that critical devices have no power downtime issue. Some rackmount IT devices, however, are not designed with power redundancy. For single-corded devices, InfraPower intelligent ATS is a perfect fit to provide power fallback. It includes dual power inlets, for connection to both a primary power source and a redundant, secondary power source
  • Remote Monitoring Over IP - InfraPower intelligent ATS provides a real time monitoring on Amp, Volt and kWh. Hence, it helps users with capacity planning and improving the overall power efficiency of the data center.
ELECTRICAL  
Nominal Input Voltage 110V
Acceptable Input Voltage ±10% Nominal
Amperage 30A
Input Frequency 50/60Hz
Inlet 2 x L5-30P
Outlets 24 x NEMA 5-20R
Local Meter 3-digit LED ammeter measuring input load current
Overload Protection (2) 16A hydraulic MCB
Transfer Time 10 - 16ms typical
Electrical Endurance 1 x 10^5 Operations
PHYSICAL  
Product (W x D x H) 437.5 (W) x 300 (D) x 88.9 (H) mm
Packing (W x D x H) 540 x 540 x 150 mm ( W x D x H )
Net Weight 6.5 kg / 14.3 lb
Gross Weight 7.0 kg / 15.4 lb
Chassis Color Dark
Chassis Material Steel
ENVIRONMENTAL  
Operating Temperature 23 to 140°F (-5 to 60°C)
Storage Temperature 13 to 149°F (-25 to 65°C)
Operating Humidity 8~95%, non-condensing
Storage Humidity 8~95%, non-condensing
COMPLIANCE  
EMC FCC Part 15 Subpart B
Safety
  • cTUVus to UL 60950-1:2007/R:2014-10
  • CAN/CSA-C22.2 No. 60950-1:2007/A2:2014-10
  • UL 62368-1:2014
  • CAN/CSA-C22.2 No. 62368-1:2014
  • UL 60730-1 Ed.5 (2016)
  • Environment RoHS3 & REACH compliant