ATS-H20C13-20A_L620 2U Single Circuit Metered ATS

InfraPower ATS-H20C13-20A_L620

  • Voltage: 208V, 50/60Hz
  • Max. Amperage: 20A
  • Power Input: (2) NEMA L6-20P
  • Outlets: (20) C13
  • Form Factor: 2U
  • Single Circuit

InfraPower Metered Automatic Transfer Switch with dual power input provides reliable and redundant power for single-corded equipment. By the input preference switch, users can define the preferred power source. If the primary source is unavailable, the ATS will seamlessly source power from the secondary source without power interruption and downtime. The entire ATS series are designed with a local current meter to easily observe power status and device load.

ATS-H20C13-20A_L620 2U Single Circuit Metered ATS - Click to enlarge


Price: $1,001.00
NOW: $858.00
Save: $143.00
Rack Units2U
Dimensions(17.2 in W x 24.8 in D x 3.5 in H)

InfraPower Metered ATS Features

  • Input Switching Locally Sometimes manual power input switching function is essential, especially during the maintenance service in data center. InfraPower® ATS is bundled with an Input Preference Switch. It allows user to set the power source preference to supply the output
  • Auto Switching Relay for Seamless Power Transfer - InfraPower® ATS offers a simple but reliable solution for automatically sensing power loss and seamlessly switching to a secondary power source. The power source transfer time is seamless to the connected equipment, making sure that the switching occurs safely between the two input power sources. After switching to a backup power source, it can also switch power back to the primary input after power has been restored.
  • Power Redundancy for Single Corded Devices - Most data centers provide power source redundancy in order to ensure that critical devices have no power downtime issue. Some rackmount IT devices, however, are not designed with power redundancy. For single-corded devices, InfraPower® ATS is a perfect fit to provide power fallback. It includes dual power inlets, for connection to both a primary power source and a redundant, secondary power source.
  • Local Amp Monitoring by Meter Most data centers provide power source redundancy in order to ensure that critical devices have no power downtime issue. Some rackmount IT devices, however, are not designed with power redundancy. For single-corded devices, InfraPower® ATS is a perfect fit to provide power fallback. It includes dual power inlets, for connection to both a primary power source and a redundant, secondary power source.
ELECTRICAL  
Nominal Input Voltage 208V
Acceptable Input Voltage ±10% Nominal
Amperage 20A
Input Frequency 50/60Hz
Inlet 2 x L6-20P
Outlets 20 x C13
Local Meter 3-digit LED ammeter measuring input load current
Overload Protection (1) 20A hydraulic MCB
Transfer Time 10 - 16ms typical
Electrical Endurance 1 x 10^5 Operations
PHYSICAL  
Product (W x D x H) (17.2 in W x 24.8 in D x 3.5 in H)
Packing (W x D x H) (21.3"W x 21.3"D x 5.9"H)
Net Weight 14.3 lbs
Gross Weight 15.4 lbs
Chassis Color Black
Chassis Material Steel
ENVIRONMENTAL  
Operating Temperature 23 to 140°F (-5 to 60°C)
Storage Temperature 13 to 149°F (-25 to 65°C)
Operating Humidity 8~95%, non-condensing
Storage Humidity 8~95%, non-condensing
COMPLIANCE  
EMC FCC Part 15 Subpart B
Safety
  • Tested to UL standard
  • Environment RoHS3 & REACH compliant