Metered-by-Outlet PDU, ZeroU, 30A, 200/208V, (21) C13 & (3) C19APC AP8441 Metered-by-Outlet Rack PDU Input: 30A - 200, 208, 230 Input Connections: NEMA L6-30P Cord Length: 10 feet (3.05 meters) Output Connections: (21) C13 & (3) C19 Output: 200, 208 Mounting: ZeroU Vertical
Includes: CAN Port Terminator, Installation guide, Rack Mounting brackets, Safety guide, Serial configuration cable
Standard Lead Time: Usually in Stock APC Metered-by-outlet Rack Power Distribution Units (PDUs) provide active metering of individual outlets to enable energy optimization and detailed capacity planning. Metered-by-outlet rack PDUs provide a more granular level of power utilization data to allow Data Center Managers to make more precise decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered-by-outlet Rack PDUs include individual outlet power metering, a temperature/humidity sensor port, alarm thresholds, and locking IEC receptacles. Users can access and configure Metered-by-outlet rack PDUs through secure Web, SNMP, or Telnet Interfaces and are complimented by APC Centralized Management platforms using StruxureWare Data Center Expert, Capacity Manager and Change Manager. |
Price: $1,800.00 NOW: $1,494.25 Save: $305.75 | Dimensions | 80.2" x 6.4" x 4.6" | |
| | APC AP8441 Specifications: Environmental | | Operating Environment | 23 - 113 °F (0 - 45 °C) | Operating Relative Humidity | 5-95% | Operating Elevation | 0-10000 feet (0-3000 meters) | Storage Temperature | -13 - 149 °F (-25 - 65 °C) | Storage Relative Humidity | 5-95% | Storage Elevation | 0-50000 feet (0-15000 meters) | Overload Protection | Yes | Conformance | | Regulatory Approvals | cUL Listed, FCC Part 15 Class A, ICES-003, IEC 60950, PSE, UL Listed, VCCI Class A | Environmental Compliance | RoHS, REACH, Battery Directive Compliant | Standard Warranty | 2 years repair or replace |
APC AP8441 Features: - Metering-by-Outlet capability: Individual outlet level power metering provides a more granular view of the power distributed to equipment within the enclosure. It also provides the ability to analyze component power trends and perform capacity planning.
- Network Management Capabilities: Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time.
- Remote Individual Outlet Control: Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).
- Alarm Thresholds: Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
- Local Current Monitoring: Display The aggregate current draw per rack PDU is displayed on the unit via a Load indicator LED. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)
- Power Delays: Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.
- Flash Upgradeable: Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)