Server Technology
Server Tech 48DCXC-04-4X070-D0NB
requires primary unit: 48DCWC-04-4X070-DONB
- Rated Amperage: 4x 70A
- Typical Power: 13.4kW
- Outputs: High Current: (4) 70A
- Circuit Protection: TPC Fuses
- Inputs: (4) -48VDC Terminal Blocks (+/- & G)
- Form Factor: 2.5U x 16"D x 17"W
Connect this ServerTech 48DCXC-04-4X070-D0NB Expansion Unit to a 48DCWC-04-4X070-D0NB Cabinet PDU using the included RJ-12 cable to control two power input circuits and manage outlets (individual or groups) under 1 IP address.
- Disconnect Rated Circuit Protection: Each output is protected by a fuse or circuit breaker and is rated for hot disconnect.
-
Output Current Monitoring: Network monitoring provides access to current draw at each output and alerts when high usage risks a tripped circuit.
-
Output Control: Cycle power to individual outputs or groups of outputs to reboot devices or to power off unused terminals.
-
Network Monitoring: The PRO1 hot-swappable network card provides for HTTP(S), SSH, Telnet,SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
-
Temperature/ Humidity Monitoring: PRO1 Primary and Expansion units each support two external 10' (3m) T/H probes. Receive SNMP-based alerts and email notifications. (Sold Separately)
-
Star Multi-Linking: PRO1 provides the ability to link up to four power circuits using one IP address. First link provides backup power to network card.
ServerTech -48VDC Family Brochure (PDF)
requires primary unit: 48DCWC-04-4X070-DONB
- Rated Amperage: 4x 70A
- Typical Power: 13.4kW
- Outputs: High Current: (4) 70A
- Circuit Protection: TPC Fuses
- Inputs: (4) -48VDC Terminal Blocks (+/- & G)
- Form Factor: 2.5U x 16"D x 17"W
Connect this ServerTech 48DCXC-04-4X070-D0NB Expansion Unit to a 48DCWC-04-4X070-D0NB Cabinet PDU using the included RJ-12 cable to control two power input circuits and manage outlets (individual or groups) under 1 IP address.
- Disconnect Rated Circuit Protection: Each output is protected by a fuse or circuit breaker and is rated for hot disconnect.
-
Output Current Monitoring: Network monitoring provides access to current draw at each output and alerts when high usage risks a tripped circuit.
-
Output Control: Cycle power to individual outputs or groups of outputs to reboot devices or to power off unused terminals.
-
Network Monitoring: The PRO1 hot-swappable network card provides for HTTP(S), SSH, Telnet,SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
-
Temperature/ Humidity Monitoring: PRO1 Primary and Expansion units each support two external 10' (3m) T/H probes. Receive SNMP-based alerts and email notifications. (Sold Separately)
-
Star Multi-Linking: PRO1 provides the ability to link up to four power circuits using one IP address. First link provides backup power to network card.
ServerTech -48VDC Family Brochure (PDF)