C2WG08HC-0ABA2DAC

Switched POPS PDU 1U Horizontal, 16A

No reviews yet
Rack Units: 1U Horizontal
Form Factor: 0U
Total Number of Outlets: 8
Voltage: 208V
Current (Amps): 20A
Phase: 1-Phase
Outlet Type: C13
Features: High Temperature Rating
Features: Locking Outlet
$1,198.00

  • Voltage: 208V 1-Ph
  • Amperage: 16A
  • Input: IEC C20 100-240V Inlet
  • Output: (8) C13
  • Form Factor: 1U Horizontal

Server Technology C2WG08HC-0ABA2DAC: Switched POPS PRO2, Per Outlet and Input Power Sensing, 1U, (8) IEC C13 Outlets, Input Amp Meter, 120-240V 20A (North America) 16A (Int'l) w/ IEC 60320 C20 Inlet, (2) Temperature/Humidity Sensor Capable, Circuit Breaker Branch Circuit Protection (Input power cord ordered separately)

Input Power Capacity (kW): 3.3
Input Plug Type: IEC C20 100-240V Inlet
Input Current (A): 16
Input Current Rated (A): 16
Input Nominal Voltage (V): 208
Input Phase: 1-Phase (L-L)
Input Cord Location: Horizontal
Total Outlets: 8
IEC C13 Count: 8

arrow_drop_downSee More Specifications

Standard Stocked: Stocked model, typically ships 7-10 business days from receipt of order.

NOTE: For the greatest compatibility, this PDU does not ship with a power cord. Please choose an appropriate cord from the accessories below.

  • Norton Secured
  • TRUSTe Verified
  • Accredited Business
 
  • Voltage: 208V 1-Ph
  • Amperage: 16A
  • Input: IEC C20 100-240V Inlet
  • Output: (8) C13
  • Form Factor: 1U Horizontal

Server Technology C2WG08HC-0ABA2DAC: Switched POPS PRO2, Per Outlet and Input Power Sensing, 1U, (8) IEC C13 Outlets, Input Amp Meter, 120-240V 20A (North America) 16A (Int'l) w/ IEC 60320 C20 Inlet, (2) Temperature/Humidity Sensor Capable, Circuit Breaker Branch Circuit Protection (Input power cord ordered separately)

Input Power Capacity (kW): 3.3
Input Plug Type: IEC C20 100-240V Inlet
Input Current (A): 16
Input Current Rated (A): 16
Input Nominal Voltage (V): 208
Input Phase: 1-Phase (L-L)
Input Cord Location: Horizontal
Total Outlets: 8
IEC C13 Count: 8

arrow_drop_downSee More Specifications

Standard Stocked: Stocked model, typically ships 7-10 business days from receipt of order.

NOTE: For the greatest compatibility, this PDU does not ship with a power cord. Please choose an appropriate cord from the accessories below.

 