Rittal TopTherm Rack Top Mount AC Unit - 400V, 2-Ph, 1.5 kW (5118 BTU)Rittal 3384540 (3383.540) TopTherm Blue roof-mounted cooling unit features a nano-coated condenser, a integral electric condensate evaporation, drilling template and assembly parts. TopTherm roof-mount units are constructed of sheet steel (RAL 7035 - Light Grey) for durability with an integral e-Comfort controller for temperature control (factory setting 95°F / 35°C). The Rittal 3384540 Energy-efficient cooling unit supports plug-in terminal strip connection, with a transformer circuit-breaker, and 100% power duty cycle for optimal performance. It operates at temperature range of 10 - 55 deg C. - Total Cooling Output (DIN EN 14511): 1.5 kW @ 50 Hz, 1.65 kW @ 60 Hz (L35/L35)
- BTU Capacity (L35/L35 60 Hz.): 5630 BTU
- Air Throughput (unimpeded):
External circuit: 942 CFM (1600 m3/h) Internal circuit: 289 CFM (491 m3/h) - Temperature Control: e-Comfort controller (factory setting 95 °F / 35°C)
- Temp. Setting Range: 68 - 131°F (20°C - 55°C)
- Input Power: 400 V, 2-Ph, 50 Hz/60 Hz - Plug-in terminal strip
- Approvals: UL, cUL, CSA, TUV Leistung, TUV Sicherheit, External circuit IP 34, Internal circuit IP 54.
- Warranty: 2 Years
Air conditioners with comfort controller may be integrated into a monitoring system with an optional interface card 3124.200 (RS 232, RS 485, RS 422 and PLC interface), for remote monitoring and control. Please Note: this item cannot be returned. Make sure to size your cooling and power requirements correctly before ordering. Standard manufacturer warranty still applies. Standard lead time is 1-15 business days for shipment. |
Price: $5,993.36 NOW: $5,762.85 Save: $230.51 | | Flexible performance Only 3 mounting cutouts for 6 different output categories in 28 design versions. | Targeted air routing in the enclosure The internal air circulation is targeted and effective: The heated air is extracted centrally. Air exhaust occurs in the four corners, based on your specific requirements. | Flexible condensate management All roof-mounted air conditioners with comfort controller are equipped with a condensate warning feature. A condensate pump and condensate evaporator may be integrated. |
TopTherm Roof-mount Manual (PDF) Rittal Manufacturer's Warranty for Climate Control Products (PDF) Energy-efficient Blue e roof-mounted cooling units in output categories from 500 W to 4,000 W, with integral e-Comfort controller, RiNano coating on the condenser and electrical condensate evaporation as standard. Protection Category IP to IEC 60 529: - External circuit IP 34 - Internal circuit IP 54 Rittal 3384540 Includes: - Nano-coated condenser - Integral electric condensate evaporation - Fully wired ready for connection (plug-in terminal strip) - Assembly parts Rittal 3384540 / 3384.540 Specifications Mechanical | | Height | 16.42" (417mm) | Width | 23.5" (597mm) | Depth | 18.7" (475mm) | Weight | 103.62 lbs. (47 kg) | Material | Sheet steel Contact us for Stainless steel option | Color | RAL 7035 (Light Grey) | Form Factor | Roof-Mount | Cooling | | BTU Capacity (L35/L35 60 Hz.) | 5630 BTU | Total cooling output to DIN EN 14511: | L 35 L 35 at 50 Hz: 1.5 kW L 35 L 35 at 60 Hz: 1.65 kW L 35 L 50 at 50 Hz: 1.15 kW L 35 L 50 at 60 Hz: 1.3 kW | Air throughput: *unimpeded air flow | External circuit: 942 CFM (1600 m3/h) Internal circuit: 289 CFM (491 m3/h) | Temperature control: | e-Comfort controller (factory setting 95°F / 35°C) | Temperature range: | Operation (environment): 50 - 131°F (10°C - 55°C) Setting range: 68 - 131°F (20°C - 55°C) | Refrigerant/cooling medium: | Refrigerant: R134a Quantity: 24.69 oz. (700 g) | Permissible operating pressure (p. max.): | 4006 psi (28 bar) | Power | | Rated operating voltage: | 400 V, 2 Phase, 50 Hz/60 Hz | Type of electrical connection: | Plug-in terminal strip | Duty cycle: | 100 % | Power consumption Pel: | L 35 L 35 at 50 Hz: 0.67 kW L 35 L 35 at 60 Hz: 0.76 kW L 35 L 50 at 50 Hz: 0.8 kW L 35 L 50 at 60 Hz: 0.93 kW | Rated current (max.): | At 50 Hz: 2.4 A At 60 Hz: 2.8 A | Start-up current max.: | At 50 Hz: 8.7 A At 60 Hz: 9 A | Pre-fuse: | Transformer circuit-breaker: 6.3 A...10 A | Energy efficiency ratio (EER) 50 Hz L35 L35 to DIN EN 14511: | 2.24 | Approvals | - UL 484 (Standard for Room Air conditioners), - cUL - CSA C22.2 No.236 (Standard for Heating and Cooling Equipment), - TUV-Geprufte Leistung - TUV-Geprufte Sicherheit | Protection Category IP to IEC 60 529: | - External circuit IP 34 - Internal circuit IP 54 | Warranty | 2 Years |
| $50.43 | 2x Polyurethane Stoppers - Cover unused air outlets - for 3209.xxx, 3210.xxx, 3273.xxx, 3383.xxx, 3384.xxx, and 3385.xxx 2x polyurethane foam stoppers to cover any cold air outlets that are not required. Stoppers are used with roof-mounted cooling units (3209.xxx, 3210.xxx, 3273.xxx, 3383.xxx, 3384.xxx, and 3385.xxx) and air/water heat exchangers. | |
| | | | | | | | | | | | |
| |
|